Protruding objects units are not to protrude more than 4 inches from the wall when closed.
Ada changing table height.
At least 27 inches of knee clearance must be provided between the floor and the underside of the table.
However the 2009 icc ansi standards limit the operable portions of dispensers in toilet compartments to no lower than 18 inches 455mm.
When the unit s bed is opened and laid flat it must provide adequate knee clearance below the station.
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed the high side reach shall be 48 inches 1220 mm maximum and the low side reach shall be 15 inches 380 mm minimum above the finish floor or ground.
Learn more about changing tables for adults with disabilities and special needs.
Install at the perfect height.
Knee clearance must extend 25 inches under a changing table and the unit must be 9 inches above the finish of the ground.
Baby changing tables shall not be located in toilet compartments complying with section 11b 604 8 within a multiple accommodation toilet.
See figure s 308 3 a below.
For adults who manage mobility limitations or incontinence they provide a safe sanitary and comfortable space for assisted changing.
Five tips for ada compliance.
For smaller spaces refer to ada section 4 2 5 forward reach.
Adult changing tables are an indispensable aid to weakened and disabled adults and their caregivers.
An accessible table has a surface height of no more than 34 inches and no less than 28 inches above the floor.
Baby changing tables shall comply with sections 11b 309 and 11b 902.
There are specific mounting heights and other requirements of baby changing stations in restrooms says ada compliance expert joan stein of stein consulting inc pittsburgh.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
For horizontal changing stations the ada requires that the unit protrude no more than 4 from the wall and be no higher than 27 inches from the floor.
They have to be mounted so that the very top of the changing table surface when it is opened cannot be any higher than 34 inches off the floor she says.
This section outlines ada guidelines pertaining to horizontal changing stations only.
Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by section 11b 307 2.